Classification of repeaters, Class i repeaters, Figure3-8 class i hub – 3Com 100 TX User Manual
Page 33: Classification of repeaters 3-9, Class i repeaters 3-9
Classification of Repeaters
3-9
Classification of
Repeaters
The IEEE 802.3 standard defines two classes of repeaters for 100BASE-T
Fast Ethernet networks, as detailed below.
Class I Repeaters
A Class I repeater is a hub with internal delay such that only one repeater can
exist between any two DTE (data terminal equipment) devices within a single
collision domain when two maximum-length cable segments are used.
The LinkBuilder FMS 100-TX Hub (product number 3C250-TX/1) is a Class I
device only.
Internal delay is the time delay between the sensing of the first data bit
received and the sensing of the first bit transmitted on a 100 Mbps CSMA/CD
network. Propagation time delays also affect repeater classification. Class I
repeater delays are longer than Class II repeater delays.
A Class I network topology consists of one hub (or hub stack) in a single collision
domain existing between any two end stations. The stack of LinkBuilder FMS
100-TX Hubs in this configuration can contain up to eight hubs.
Figure 3-8 shows a single collision domain containing one Class I hub stack
between two end stations, with the distance between end stations being
200 meters. If one of the hub-to-node segments is implemented with fiber
cabling (by using the 100BASE-FX transceiver interface module), the total
span can be 260.8 meters. That is, up to 100 meters can consist of UTP
cabling, with up to 160.8 meters of fiber cabling.
Figure 3-8 Class I Hub
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
Class I configuration
200 meters: maximum UTP distance
(260.8 meters: mixed UTP and fiber cable)
100 meters maximum
(160.8 meters: fiber cable)
100 meters maximum