beautypg.com

Transceiver interface module cabling requirements, 100base-tx: two pairs of category 5 twisted-pair u, 100base-fx: two-strand fiber-optic cabling (62.5/1 – 3Com 100 TX User Manual

Page 40: Topology rules, Hub to connected workstations, Figure4-1 connecting the hub to a workstation, Hub to connected workstations 4-2, Figure 4-1 connecting the hub to a workstation, Activity, Link partition clsii

background image

4-2

C

HAPTER

4: C

ABLING

Transceiver
Interface Module
Cabling
Requirements

The two transceiver interface modules provide downlink connectivity to
another hub or to a bridge, router, or switch. For transceiver interface
module connections, the hub supports 100BASE-T functionality using the
following media specifications:

100BASE-TX: two pairs of Category 5 twisted-pair UTP wire

100BASE-FX: two-strand fiber-optic cabling (62.5/125

µ

multimode cable)

Topology Rules

The key 100BASE-T topology rules are illustrated in this section.

Hub to Connected

Workstations

The maximum UTP cable length between the hub and connected
workstations is 100 meters. (See Figure 4-1.)

Figure 4-1 Connecting the Hub to a Workstation

Straight-through UTP cable
(100 meters maximum)

1 . . . . . . .8

®

LinkBuilder FMS 100

100BASE-TX Hub

1x

2x

3x

4x

5x

6x

7x

100BT

STATUS

8x

9x

10x

11x

12x

1 2

3 4

5 6

7 8

9 10

11 12

13

ACTIVITY

UNIT

LINK

PARTITION

CLSII

3C250-TX/

Ι

CLSI

PWR

FAN FAIL

OVERTEMP

COLLISION