Xantrex Technology XTR 850 Watt User Manual
Page 98

Analog Programming (APG) and Isolated Analog Programming (ISOL)
4-6
975-0200-01-01
J1.9
VOL_PR
Analog Voltage Programming Input
J1.10
CUR_PR
Analog Current Programming Input
J1.11
VOL_RES_PR
Voltage Resistive Programming
J1.12
CUR_RES_PR
Current Resistive Programming
J1.13
VOL_MON
Voltage Monitor. Scaled to the value of the Voltage Analog
Programming Level.
J1.14
CUR_MON
Current Monitor. Scaled to the value of the Current Analog
Programming Level.
J1.15
EXT_CC_CV
External CC/CV. Indicates the state of the operate mode. When
in CV mode, logic high is output and when in CC mode, logic
low is output. Logic is TTL/CMOS compatible.
J1.16
CSH
Current Share. Used to hook up units for current sharing. Output
from master unit. Slave units left open.
J1.17
REF_I
Current Reference Input. Slave input from current share pin on
master unit.
J1.18
NC
Table 4-3 APG Pins and Functions J1
Pin
Reference
Function