Common specifications for all models – Xantrex Technology XTR 850 Watt User Manual
Page 257

975-0200-01-01
C-7
Common Speci
fications for All M
o
del
s
C
Common Specifications for All Models
Output Voltage and Current Monitor
0–100%, 2~ up to 10 V, programmable
On/Off Control
TTL level
AUX On/Off Control
TTL level or dry contact
Power Supply Status Signal
TTL high: OK
TTL low: fail
Interlock Enable/Disable
Dry contact. Open/Short: On or Off,
programmable
Output Performance Specifications
Temperature Coefficient
100 PPM/° C from rated output voltage, after a 30-minute warm-up
Drift (8 hours)
0.05% of rated output (over an 8 hour interval with constant line, load and temperature, after a 30-minute warm-up)
Hold-up Time
Typical 20 ms at any rated input line.
Transient Response Time
1
1.Time for the output voltage to recover within 0.5% at its rated output for a load change 10–90% of rated output current. Output set point
10–100%.
Less than 1 ms for 6 V to 60 V models. Less than 2 ms for 80 V to 600 V models
Meter Accuracy
0.5% ± 1 count
Isolation
AC Input to Output
AC Input to Chassis
Output to Chassis
1350 Vac
1350 Vac
500 Vac
Table C-3 Remote Operation
Programming Mode
APG
ISOL
Digital