Resetting activated foldback protection, Resetting activated foldback protection –23 – Xantrex Technology XTR 850 Watt User Manual
Page 71

Setting Foldback Mode
975-0200-01-01
3-23
3
4. Press the Rotary knob/Enter button to commit the setting once the
desired value has been set.
5. The green FLD LED will turn off and the display will return to the
normal display mode.
The SCPI command (s) for these instructions are:
[:]OUTPut[
[:]OUTPut[
Resetting Activated Foldback Protection
To reset activated and latched foldback protection, press and hold the
Rotary knob/Enter button for approximately 3 seconds.
The SCPI command (s) for these instructions are:
[:]OUTPut[
Important:
If you set foldback while the output is enabled and the trigger you
select is the same as the current operating mode, the foldback timer will begin
counting immediately after the delay time has been set.