Current share sub-register, Current share sub-register –35, Table 5-12 – Xantrex Technology XTR 850 Watt User Manual
Page 157: Operation shutdown status register –35, Table 5-13, Operation shutdown protection status register –35

OPERation Status Register
975-0200-01-01
5-35
5
Current SHare Sub-Register
This register shows the state of the current share configuration, which can
either be set through the front panel Current Share Config menu, or
through the SCPI command.
The SCPI command (s) for these instructions are:
[[:]SOURce]:COMBine:CSHare[:MODE]
Table 5-12 OPERation SHUTdown Status Register
Bit
Bit Weight
Bit Name
Description
0
1
PROTection
Reflects the summary of the PROTection sub-
register.
1
2
INTerlock
The power supply is shut down by INTerlock signal.
2
4
Not Used
Not Used
3
8
External Shutdown
The power supply is shut down by External
Shutdown signal.
Table 5-13 OPERation SHUTdown PROTection Status Register
Bit
Bit Weight
Bit Name
Description
0
1
OVP
Over Voltage protection has tripped.
1
2
UVP
Under Voltage protection has tripped.
2
4
Not Used
Not Used
3
8
Not Used
Not Used
4
16
AC Off
AC failure protection has tripped.
5
32
OTP
Over Temperature protection has tripped.
6
64
Not Used
Not Used
7
128
Foldback
Foldback protection has tripped.
8
256
Fan
Fan failure protection has tripped.