Scpi command summary, Table a-1 – Xantrex Technology XTR 850 Watt User Manual
Page 222

A-14 975-0200-01-01
S
C
PI
C
o
mm
an
d
R
e
fe
re
n
ce
SCPI Command Summary
The SCPI commands supported by this programmable power supply are described in the
tables in the remainder of this section. These tables use the following column headings:
•
Function The commonly used name for the function.
•
SCPI Command The full command in long form.
•
Description Explains what the command does or what is affected by it.
•
Query? Indicates whether the unit supports a query version of the listed command. N/A
indicates Not applicable. (The command has no query form and will respond with an error
if queried.)
Table A-1 IEEE 488.2 Commands
Function
SCPI Command
Description
Parameter and
Range
Query
Select
Address
*ADR
Select the power supply unit
to communicate with.
?|
Yes
Clear Status
*CLS
[:]STATus[
Clears all the status data
structures.
N/A
Query the
Error Queue
*ERR
Query the Error Queue for
the oldest error event.
Standard
Event Status
Enable Query
*ESE?
[:]STATus[
Query the Standard Event
Status Enable register
settings.
Yes
Standard
Event Status
Enable
*ESE
[:]STATus[
Set the Standard Event
Status Enable Register bits.
N/A
Standard
Event Status
Register
Query
*ESR?
[:]STATus[
Query the Standard Event
Status Register (SERS).
Yes