Table a-5, Table a-6, Table a-7 – Xantrex Technology XTR 850 Watt User Manual
Page 229

SPC
I Co
mmand T
ree
975-0200
-01-01
A-21
A
Table A-5 SCPI Commands to Clear All Protection Mechanisms
Function
SCPI Command
Description
Parameter and
Range
Query
Clear Output
Protection
[:]OUTPut[
Clears the currently set
alarms.
N/A
Table A-6 SCPI Commands for Foldback Protection
Function
SCPI Command
Description
Parameter and
Range
Query
Set Output
Foldback
Delay
[:]OUTPut[
:FOLDback:DELay
Set the delay time (seconds)
before foldback protection
is triggered.
?|
Set Output
Foldback
Mode
[:]OUTPut[
:FOLDback[:MODE]
Select condition for
foldback.
?|CV|CC|NONE
Yes
Table A-7 SCPI Commands for Power
Function
SCPI Command
Description
Parameter and
Range
Query
Shutdown
Logic Control
[:]OUTPut:POLarity
Sets the TTL level that will
trigger an External
Shutdown.
?|HIGH|LOW
Yes
Main Output
Control
[:]OUTPut[:POWer][:STATe]
Control Main Output State
(Enable/Disable)
?|ON|OFF
Yes
Power On
Main Output
Control
[:]OUTPut[:POWer]:PON[:STATe]
Control Main Output
Autostart State (Enable/
Disable)
?|ON|OFF
Yes
Aux Output
Control
[:]OUTPut:AUXilliary[:STATe]
Control Aux Output State
(Enable/Disable)
?|ON|OFF
Yes