ACS-ATM Card User Screens and Settings

ATM Card

Table 4-1. ACS-ATM Card Main Screen Actions (DS3)

Table 4-2. ACS-ATM Card Main Screen Options and Defaults (DS3)

STATE (DS3)

The State setting determines whether the port is active or inactive. Set State to stdby (standby)
for ports not being used or not yet configured. Set it to actv (active) for ports that are ready
for use for ATM traffic.

FORMAT (DS3)

The Format setting indicates the variety of DS3 C-bit application used by this port. The
choices are Cbit and M23. This parameter is defined in RFC 1407.

CELL FRM (DS3)

The Cell Framing setting indicates the way ATM cells are constructed from the DS3 bitstream.
The two options are plcp (cells are constructed from the PLCP mapping bits) and hcs (the cells
are constructed from the HEC in the cell header).

Action

Function

Save

Saves changes to settings.

Undo

Returns all settings to the last saved state.

Refresh

Redraws the screen.

uNi

Brings up the User Network Interface (UNI) Configuration Screen.

Vbr

Brings up the Variable Bit Rate (VBR) Configuration Screen.

Cbr

Brings up the Constant Bit Rate (CBR) Configuration Screen.

Perf

Brings up the DS3 Port Performance Data Screen.

Main

Returns to the System Main Screen. If changes are made to settings and not
saved, you will be prompted to save or lose changes.

Parameter

User Options

Default

STATE

stdby actv

stdby

FORMAT

Cbit M23

Cbit

CELL FRM

plcp hcs

plcp

LB CFG

off local line payld cell

off

LB GEN

off line paylod reset

off

LB DET

off on w/to

off

TX CLKSRC

line plcp

line

TX-RX SCRAM

yes no

yes

TX-LBO

off on

off

IDLE-UASN

uasn idle

uasn