Server Cards

Model No.

Running Head

Inverse Multiplexer (IMUX) Card Settings

IMUX Card

TXDISC TIMER

The Timer (bothway) Disconnect setting defines the duration of time necessary for sending
the disconnect indication prior to disconnecting the call. The values (in milliseconds) are
1000, 2000, 3000 and 4000. This timer is used for mode1 calls.

TCID TIMER

The Timer Channel Identifier setting defines the duration of time spent by the network looking
for secondary B channel allocation information before disconnecting the call. The values (in
milliseconds) are 1000, 2000, 3000 and 4000. This timer is used for mode2 and mode3 calls
(when available).

TANULL TIMER

The Timer (answer) Null State setting defines the duration of time spent by the called user
looking for bonding information before disconnecting the call. The values (in milliseconds)
are 5000, 2500, 7500 and 10000. This timer is used for mode0 and mode1 calls.

TXDEQ TIMER

The Timer (bothway) Delay Equalization setting defines the duration of time given the called
user to complete equalization of the call. The values (in milliseconds) are 20000, 10000,
30000 and 50000. This timer is used for mode1 calls.

TXFA TIMER

The Timer (bothway) Frame Alignment setting defines the duration of time (per channel) for
the called user needs to find frame alignment. The values (in milliseconds) are 20000, 10000,
30000 and 40000. This timer is used for mode1 calls.

Table 7-10. The IMUX Call Screen Actions

Action

Function

Save

Saves changes to settings.

Undo

Returns all settings to the last saved state.

Refresh

Updates certain time-related information fields that are not automatically
updated (i.e. performance and test data).

Main

Returns to the HSU call profile screen. If changes are made to settings and
not saved, you will be prompted to save or lose changes.