Communications Interface

RS-232 at 110 to 19,200 baud (select from standard rates). Baud

rate, data bits, parity, error detection protocol, and XON-XOFF or

DTR/DSR handshaking are all switch-selectable. Stop bits are fixed

at 1

Compatibility Mode Parallel Interface. Maximum cable length: 10 ft.

(304.8 cm)

Environmental Ranges

Operating temperature

+41°F to +104°F

+5°C to +40°C

Storage temperature

-40°F to +158°F

40°C to +70°C

Non-condensing relative

humidity

Operating

20% to 85%

Storage

20% to 85%

Options and Accessories

Peel-Off capability only*

Cutter Module

Cutter Catch Tray

Media Rewind with rewind and peel-off capabilities*

Fanfold Supply Bin

ZebraNet™

Black-Mark (Reflective) Sensor (105Se only)

Scalable and bit-mapped smooth fonts

Additional 512 KB memory (not available for 105Se [300 dots/inch])

* Peel Off and Media Rewind options are mutually exclusive of the

Cutter option.