Regarding The Indicator Lamps (continued)

STANDBY/

ON indicator

LAMP

indicator

TEMP

indicator

Description

Lighting in

Red

Blinking in

Red

Turned off

Either there is no lamp and/or lamp cover, or
either of these has not been properly fixed.

Please turn the power off, and allow the unit to

cool down at least 45 minutes. After the projector

has sufficiently cooled down, please make confir-
mation of the attachment state of the lamp and

lamp cover, and then turn the power on again.

If the same indication is displayed after the treat-

ment, please contact your dealer or service com-

pany.

Lighting in

Red

Turned off Blinking in

Red

The cooling fan is not operating.
Please turn the power off, and allow the unit to

cool down at least 20 minutes. After the projector

has sufficiently cooled down, please make confir-

mation that no foreign matter has become caught
in the fan, etc., and then turn the power on again.

If the same indication is displayed after the treat-

ment, please contact your dealer or service com-

pany.

Lighting in

Red

Turned off Lighting in

Red

There is a possibility that interior portion has

become heated.
Please turn the power off, and allow the unit to

cool down at least 20 minutes. After the projector

has sufficiently cooled down, please make confir-

mation of the following items, and then turn the
power on again.

• Is there blockage of the air passage aperture?

• Is the air filter dirty?

• Does the peripheral temperature exceed 35°C?

If the same indication is displayed after the treat-

ment, please change the lamp by referring to the

section “Lamp”.

Lighting in

Green

Alternative Blinking in

Red

There is a possibility that interior portion has

become overcooled.

Please use the projector within the usage temper-

ature parameters (0°C to 35°C). After the treat-

ment, resent the power to on.

Lighting in

Green

Simultaneous Blinking

in Red

It is time to clean the air filter, or there is no air

filter.

Please immediately turn the power off, and clean

or change the air filter by referring to the section

“Air Filter”. After cleaning or changing the air filter,

please be sure to reset the filter time. After the

treatment, resent the power to on.