beautypg.com

Air filter, Caring for the air filter – VIEWSONIC PJ1165 User Manual

Page 40

background image

ViewSonic PJ1165

39

Air Filter

Caring For The Air Filter

The air filter should be cleaned about every 100 hours. If the indicators or a message

prompts you to clean the air filter, clean the air filter as soon as possible. If the soiling will

not come off the air filter, or it becomes damaged, then it needs to be replaced. Pleas e

replace the air filter as soon as possible.

memo

When you replace the lamp, please replace also the air filter.

1

Turn off the projector, and unplug the power cord. Allow the lamp bulb to cool for at least
45 minutes.

2

After making sure that the projector has
cooled adequately, remove the filter cover
and the air filter.

3

Apply a vacuum cleaner to the filter cover and
the air filter to clean.

If the soiling will not come off the air filter, or it

becomes damaged, it needs to be replaced.
If the air filter needs to be replaced, contact

your dealer to prepare A new air filter. Tell the

dealer you’re air filter type.

4

Insert the cleaned air filter or a new air filter,
and replace the filter cover.

5

Turn on the projector power, and reset the
filter timer.

(1) While the projector running, press the

MENU button to open the menu.

(2) Choose the “OPTION” on the menu using

the S/T button, then press the X button

or ENTER button.

(3) Choose the “FILTER TIME” using the S/

T button, then press and hold the RESET button for 3 seconds.

(4) Choose the “RESET” using the S button.

memo

Incorrectly resetting of the filter timer (resetting without replacement, or neglect of

resetting after replacement) will result in incorrect message functions.

WARNING

• Please carefully read the “Quick Start Guide”.
• Before caring the air filter, make sure the power switch is off and the power cable is not

plugged in, then to replacing wait at least 45 minutes for the lamp to cool sufficiently.

• Use only the air filter of the specified type. Please call ViewSonic Tech Support for P/N.
• Do not use the projector with the air filter and filter cover removed. The use without the

air filter could result in damage.

CAUTION

• If the air filter becomes clogged by dust or the like, internal temperature rises and could

cause malfunction. The power is automatically turned off in order to prevent the

projector from overheating internally.

Hold the release but-

tons of the filter cover

while pulling down it.

Hold the release button

of the air filter while pull-

ing out it.