beautypg.com

Regarding the indicator lamps – VIEWSONIC PJ1165 User Manual

Page 43

background image

ViewSonic PJ1165

42

Regarding The Indicator Lamps

Lighting and blinking of the STANDBY/ON indicator, the LAMP indicator and the TEMP

indicator have the meanings as described in the table below. Please respond in according

with the instructions within the table. If the same indication is displayed after the treatment,

or if an indication other than the following is displayed, please contact your dealer or service

company.
NOTE

• When the interior portion has become overheated, for safety purposes, the power

source is automatically turned off, and the indicator lamps may also be turned off. In

such a case, press the [O] (Off) side of the main power switch, and wait at least

45minutes. After the projector has sufficiently cooled down, please make confirmation of

the attachment state of the lamp and lamp cover, and then turn the power on again.

(This table is continued to the following page.)

STANDBY/

ON indicator

LAMP

indicator

TEMP

indicator

Description

Lighting in

Orange

Turned off Turned off The projector is in a standby state.

Please refer to the section “Power On/Off”.

Blinking in

Green

Turned off Turned off The projector is warming up.

Please wait.

Lighting in

Green

Turned off Turned off The projector is in an on state.

Ordinary operations may be performed.

Blinking in

Orange

Turned off Turned off The projector is cooling down.

Please wait.

Blinking in

Red

(discretion-

ary)

(discretion-

ary)

The projector is cooling down. A certain error
has been detected.

Please wait until the STANDBY/ON indicator fin-
ishes blink, and then perform the proper response
measure using the item descriptions below as ref-
erence.

Lighting in

Red

Lighting in

Red

Turned off

The lamp does not light, and there is a

possibility that interior portion has become

heated.
Please turn the power off, and allow the unit to

cool down at least 20 minutes. After the projector

has sufficiently cooled down, please make

confirmation of the following items, and then turn

the power on again.
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the

treatment, please change the lamp by referring to

the section “Lamp”.