25

The column order and width of the event log window are saved to the registry of the computer.
Up to 1000 of events can be stored. If it exceeds 1000 events, the oldest event is deleted and the

latest event is added. The event log can be saved to the management file.

This Warning column is not available for some projector's model types.

Description of warning value

The warning value with "*" in the above table shows the

event when the alert has cleared, alert type is "OFF".

Description of Event, Type, Warning column, Warning value

Warning Column

Warning Value

Description

Connect

Un-connected
Connected *
Acquisition error

Projector has been disconnected from the network
Projector has been connected to the network
PJ Network Manager could not acquire the MIB information
from the equipment

Power status

Power failure

Projector turned off due to the power failure of the projector

TemperatureError

The projector turned off due to temperature error occurred

Normal (AfterTempError)

Normal after temperature error occurred

RS232CFailure

The RS-232C communication error occurred

Power management

The power management function turned projector lamp off

Shutter management

The shutter management function turned projector lamp off

LampFailure

The lamp failure occurred

Normal(Standby) *

Projector turned into standby normally

Normal(OnCoolingDown) *

On cooling down normally due to projector turned off

Input signal status

SignalsInterrupted
SignalsInputted *

The signal was interrupted
The signal was inputted again

Inside Temperature status (A to
C)
External Temperature status

Abnormal

The projector turned off when the temperature was
abnormally high

Lamp status

ON *
Failure
Replace

When the lamp is on
When the lamp failed to ignite.
It reached lamp replacing time.

Lamp time

(lamp time)

It reached user setting lamp replacing time

Filter status

Clogged
Warning

Filter has been clogged
Filter is close to clogging

Filter time

(filter time)

It reached user setting filter time

(Auto play error)

n/a

The error occurred during the auto image display

(WarningOnConstantModeFor
Brightness)

n/a

The brightness (Current value) continuously goes down a cer-
tain rate from the value in Constant mode.