Customizing the status list

Changing the status column indication

1

Select Column selection from System menu. The col-
umn selection window will appear.

2

On the window, check the column name to be indi-
cated on the status list.

The mark [*] next to the column name indicates alert item.

3

To change the order of the display column on the

status list, select a column you intend to change the
order and click To up or To down button.

4

Click OK to close setting.

When specifying the column width by numeric value, enter

number (0 to 9999) onto "Column width" text box.

Column

Description

*Target name ............................Name of the network equipment
*Group...........................................Group name
*Connect......................................Status of connection to the network (Connected, Un-connected)
*Drive time .................................Accumulated use time of the equipment
*Power status............................Power status of the equipment (Normal(Power-on), Normal(Standby), Power

Management, Power failure, lamp failure, etc.)

*Input status..............................Input signal status (Signal, No signal, Signal interrupted)
*Inside Temperature

A status....................................Status of inside temperature A (Normal, Warning, Error)

*Inside Temperature

B status ....................................Status of inside temperature B (Normal, Warning, Error)

*Inside Temperature

C status....................................Status of inside temperature C (Normal, Error)

*External Temperature

status.........................................Status of external temperature (Normal, Warning, Error)

*Lamp1 status ..........................Status of Lamp1 (Off, On, Error, Replace)
*Lamp2 status ..........................Status of Lamp2 (Off, On, Error, Replace)
*Lamp3 status ..........................Status of Lamp3 (Off, On, Error, Replace)
*Lamp4 status ..........................Status of Lamp4 (Off, On, Error, Replace)
*Lamp1 time..............................Used time of Lamp1
*Lamp2 time..............................Used time of Lamp2
*Lamp3 time..............................Used time of Lamp3
*Lamp4 time..............................Used time of Lamp4
*Filter status...............................Status of airfilter (Normal, Clogged)
*Option Box

filter status ............................Status of option box filter (Normal, Error, Clogged)

*Filter time..................................Use time of airfilter
*Option Box

filter time................................Use time of option box filter

The values in parentheses are typical value and they differ depending on the connected equipment.
The [*] next to the column name indicates alert items.