2.12.8

VDP General Line Mode and Line Address Register

Subaddress

80 0600h−80 0611h

(default line mode = FFh, address = 00h)

Subaddress

7

6

5

4

3

2

1

0

80 0600h

Line address 1

80 0601h

Line mode 1

80 0602h

Line address 2

80 0603h

Line mode 2

80 0604h

Line address 3

80 0605h

Line mode 3

80 0606h

Line address 4

80 0607h

Line mode 4

80 0608h

Line address 5

80 0609h

Line mode 5

80 060Ah

Line address 6

80 060Bh

Line mode 6

80 060Ch

Line address 7

80 060Dh

Line mode 7

80 060Eh

Line address 8

80 060Fh

Line mode 8

80 0610h

Line address 9

80 0611h

Line mode 9

Line address [7:0]: Line number to be processed by a VDP set by a line mode register (default 00h)
Line mode register [7:0]:

Bit 7:

0 = Disabled filters
1 = Enabled filters for teletext and CC (null byte filter) (default)

Bit 6:

0 = Send sliced VBI data to registers only (default)
1 = Send sliced VBI data to FIFO and registers, teletext data only goes to FIFO (default)

Bit 5:

0 = Allow VBI data with errors in the FIFO
1 = Do not allow VBI data with errors in the FIFO (default)

Bit 4:

0 = Disabled error detection and correction
1 = Enabled error detection and correction (teletext only) (default)

Bit 3:

0 = Field 1
1 = Field 2 (default)

Bits [2:0]:

000 = Teletext (WST625, Chinese teletext, NABTS 525)
001 = CC (US, Europe, Japan, China)
010 = WSS (525, 625)
011 = VITC
100 = VPS/PDC (PAL only), Gemstar (NTSC only)
101 = USER 1
110 = USER 2
111 = Reserved (active video) (default)