beautypg.com

Figure 6-21 – Texas Instruments TMS320F2802 User Manual

Page 122

background image

Data Valid

11

SPISOMI

SPISIMO

SPICLK

(clock polarity = 1)

SPICLK

(clock polarity = 0)

Master In Data Must

Be Valid

Master Out Data Is Valid

1

7

6

10

3

2

SPISTE

(A)

TMS320F2809, TMS320F2808, TMS320F2806
TMS320F2802, TMS320F2801, TMS320C2802
TMS320C2801, TMS320F28016, TMS320F28015

SPRS230N – OCTOBER 2003 – REVISED MAY 2012

www.ti.com

A.

In the master mode, SPISTE goes active 0.5t

c(SPC)

(minimum) before valid SPI clock edge. On the trailing end of the word, the SPISTE will go inactive 0.5t

c(SPC)

after

the receiving edge (SPICLK) of the last data bit, except that SPISTE stays active between back-to-back transmit words in both FIFO and non-FIFO modes.

Figure 6-21. SPI Master Mode External Timing (Clock Phase = 1)

122

Electrical Specifications

Copyright © 2003–2012, Texas Instruments Incorporated

Submit Documentation Feedback

Product Folder Link(s):

TMS320F2809 TMS320F2808 TMS320F2806 TMS320F2802 TMS320F2801 TMS320C2802

TMS320C2801 TMS320F28016 TMS320F28015