Table 6-34 – Texas Instruments TMS320F2802 User Manual
Page 119

SPRS230N – OCTOBER 2003 – REVISED MAY 2012
Table 6-34. SPI Master Mode External Timing (Clock Phase = 0)
(1) (2) (3) (4) (5)
SPI WHEN (SPIBRR + 1) IS EVEN OR
SPI WHEN (SPIBRR + 1) IS ODD AND
SPIBRR = 0 OR 2
SPIBRR > 3
NO.
UNIT
MIN
MAX
MIN
MAX
1
t
c(SPC)M
Cycle time, SPICLK
4t
c(LCO)
128t
c(LCO)
5t
c(LCO)
127t
c(LCO)
ns
t
w(SPCH)M
Pulse duration, SPICLK high
0.5t
c(SPC)M
– 10
0.5t
c(SPC)M
0.5t
c(SPC)M
– 0.5t
c(LCO)
– 10
0.5t
c(SPC)M
– 0.5t
c(LCO)
(clock polarity = 0)
2
ns
t
w(SPCL)M
Pulse duration, SPICLK low
0.5t
c(SPC)M
– 10
0.5t
c(SPC)M
0.5t
c(SPC)M
– 0.5t
c(LCO)
– 10
0.5t
c(SPC)M
– 0.5t
c(LCO)
(clock polarity = 1)
t
w(SPCL)M
Pulse duration, SPICLK low
0.5t
c(SPC)M
– 10
0.5t
c(SPC)M
0.5t
c(SPC)M
+ 0.5t
c(LCO)
– 10
0.5t
c(SPC)M
+ 0.5t
c(LCO)
(clock polarity = 0)
3
ns
t
w(SPCH)M
Pulse duration, SPICLK high
0.5t
c(SPC)M
– 10
0.5t
c(SPC)M
0.5t
c(SPC)M
+ 0.5t
c(LCO)
– 10
0.5t
c(SPC)M
+ 0.5t
c(LCO)
(clock polarity = 1)
t
d(SPCH-SIMO)M
Delay time, SPICLK high to SPISIMO
10
10
valid (clock polarity = 0)
4
ns
t
d(SPCL-SIMO)M
Delay time, SPICLK low to SPISIMO
10
10
valid (clock polarity = 1)
t
v(SPCL-SIMO)M
Valid time, SPISIMO data valid after
0.5t
c(SPC)M
– 10
0.5t
c(SPC)M
+ 0.5t
c(LCO)
– 10
SPICLK low (clock polarity = 0)
5
ns
t
v(SPCH-SIMO)M
Valid time, SPISIMO data valid after
0.5t
c(SPC)M
– 10
0.5t
c(SPC)M
+ 0.5t
c(LCO)
– 10
SPICLK high (clock polarity = 1)
t
su(SOMI-SPCL)M
Setup time, SPISOMI before SPICLK
35
35
low (clock polarity = 0)
8
ns
t
su(SOMI-SPCH)M
Setup time, SPISOMI before SPICLK
35
35
high (clock polarity = 1)
t
v(SPCL-SOMI)M
Valid time, SPISOMI data valid after
0.25t
c(SPC)M
– 10
0.5t
c(SPC)M
– 0.5t
c(LCO)
– 10
SPICLK low (clock polarity = 0)
9
ns
t
v(SPCH-SOMI)M
Valid time, SPISOMI data valid after
0.25t
c(SPC)M
– 10
0.5t
c(SPC)M
– 0.5t
c(LCO)
– 10
SPICLK high (clock polarity = 1)
(1)
The MASTER / SLAVE bit (SPICTL.2) is set and the CLOCK PHASE bit (SPICTL.3) is cleared.
(2)
t
c(SPC)
= SPI clock cycle time = LSPCLK/4 or LSPCLK/(SPIBRR +1)
(3)
t
c(LCO)
= LSPCLK cycle time
(4)
Internal clock prescalers must be adjusted such that the SPI clock speed is limited to the following SPI clock rate:
Master mode transmit 25-MHz MAX, master mode receive 12.5-MHz MAX
Slave mode transmit 12.5-MAX, slave mode receive 12.5-MHz MAX.
(5)
The active edge of the SPICLK signal referenced is controlled by the clock polarity bit (SPICCR.6).
Copyright © 2003–2012, Texas Instruments Incorporated
Electrical Specifications
119
Product Folder Link(s):