8

case where the user is trying to transfer a call from an inactive GW port (the user input is
shown in bold).

calltransfer 1 999999

*R Invalid gateway id

ERROR

Parameter Setting Commands are commands that set a system parameter to a specific value.
E.g.: The command ippassword sets the valid password needed to establish an IP connection
with the GW to a specific value.

If the command is syntactically correct the GW returns OK, otherwise the GW returns
ERROR. If *P parameter feedback is activated (ref. command feedback), and the parameter
is successfully changed, the GW will return the command with the new value. An example of
*P parameter feedback is shown below (the user input is shown in bold).

pardial on

OK

*P pardial on

When issuing a Parameter Setting Command with no parameter, the GW will return the
command with the current setting. E.g.:

pardial

*P pardial on

OK

Status Commands are commands that list different sets of system parameters. If *S status
feedback
is activated (ref. command feedback), status commands are automatically called
when corresponding parameters are being changed.

4.2. The

commands

The commands are divided into five groups: System Configuration Commands, General GW
Commands, System Status Commands, Debug Commands and Special Commands.