TANDBERG GW Dataport Command Interface D13202 User Manual
Page 26

TANDBERG GW
Dataport Command Interface User Guide
D13202 Rev 01
26
•
PRI interface: a/b/c/d. Letters identifying the different PRI interfaces.
o
a: PRI interface 1
o
b: PRI interface 2
o
c: PRI interface 3
o
d: PRI interface 4
•
status: disabled / red alarm / blue alarm/ yellow alarm / synced /
active
•
total numb. of channels: Total number of ISDN B channels.
•
B chans free: Total number of free B channels, i.e. B channels currently
not in use.
•
H0 chans free: Total number of free H0 channels, i.e. H0 channels
currently not in use.
Example of pristatus feedback:
*S pristatus b active 30 24 3
statin
Gives status for incoming calls.
statin [callid]
Status format:
statin
Parameters:
•
callid: 1..16/32. Identifier referring to a call.
•
call-dir: incoming/outgoing
•
call-state: idle/syncing/capex/unframed/speech/disconn/synced
•
restrict: idle/norestrict/restrict
•
chan: unknown / idle / speech / h323-voip / h221-
•
audio: unknown / idle / g728 / g722 / g722.1 / g711 / auoff
•
vidmode: unknown / vidoff / h261 / h263
•
vidres: unknown / cif / qcif / sqcif / 4cif / sif / 4sif // vga / svga / xga
•
duores: cif / qcif / sqcif / 4cif / sif / 4sif / vga / svga / xga
Example of statin feedback:
*S statin 1 outgoing sstatinynced norestrict h323-1920 g722 h263 cif unknown
*S statin 1 outgoing synced norestrict h323-1920 g722 h263 cif unknown
statout
Gives status for outgoing calls.
statout[callid]
Status format:
statout
Parameters:
•
callid: 1..16/32. Identifier referring to a call.
•
call-dir: incoming/outgoing
•
call-state: idle/syncing/capex/unframed/speech/disconn/synced
•
restrict: idle/norestrict/restrict
•
chan: unknown / idle / speech / h323-voip / h221-
channels.
•
audio: unknown / idle / g728 / g722 / g722.1 / g711 / auoff
•
vidmode: unknown / vidoff / h261 / h263