Piou/pious/rssu/rsiu setup – Toshiba Strata DK Backup User Manual
Page 138
PIOU/PIOUS/RSSU/RSIU Setup
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
128
DKAdmin/DKBackup
♦
DKAdmin/DKBackup PC directly connected to the Strata DK – 50 feet maximum (see
Figure 16
on
Page 130
).
♦
DKAdmin/DKBackup PC connected to Strata DK via Toshiba Data Interface Units – 1000
feet maximum (see
Figure 17
on
Page 131
).
♦
DKAdmin/DKBackup PC remote modem connected to Strata DK system external
modem/TTY port (direct modem to modem call)(see
Figure 18
on
Page 132
).
♦
DKAdmin/DKBackup PC remote modem connected to Strata DK system built-in IMDU,
RMDS (or external modem) – voice call first, then modem to modem connection (see
Figure 19
on
Page 133
).
♦
DKAdmin/DKBackup PC remote modem connected to Strata DK modem pool – then auto
dial modem pool DIU to Strata DK DIU/TTY port (see
Figure 20
on
Page 135
).
♦
DKAdmin/DKBackup PC DIU/DIU modem pool connected to Strata DK system modem
– voice call first, then modem to modem connection (see
Figure 21
on
Page 137
).
♦
DKAdmin/DKBackup PC DIU/DIU modem pool connected to Strata DK system modem
– DIU to DIU connection, then modem to modem connection (see
Figure 22
on
Page 139
).
PIOU/PIOUS/RSSU/RSIU Setup
➤
To check the DKAdmin/DKBackup communications setup
1. From the Options/System Installation/Communication Setup menu, verify that the proper
COM port is selected and that the communications parameters are set as follows:
2. PIOU or PIOUS PCB installed on Strata DK which is connected to DKAdmin/DKBackup
PC: if using an IMDU, verify that the switch SW2 is set for 1200 bps (LED CD4 off) and
that SW3 is set to “MODEM.”
If connecting an external modem, PDIU-DS, or PC COM port directly to the TTY
modular jack, verify SW2 is set to the “TTY” position.
3. RSSU does not support the IMDU built-in modem or SMDR, and it has no option
switches. Its communication parameters (TTY port) are always 1200 bps, even parity, 7
data bits, 1-stop bit.
4. Use Program 03 to identify the PCB slot that contains the PCB with the TTY port or
modem that will be used (Code 41 for PIOU, PIOUS, or RSSU or Code 49 for RSIU).
5. Use Program 76 if RSIU/RSIS/RMDS is used to connect with the DKAdmin/DKBackup
PC.
6. Use Program 77-1 (LED 14 and 15) if IMDU or RMDS is used to connect to the
DKAdmin/DKBackup PC.
Communications port:
COMX (X = 1, 2, 3 or 4)
Baud rate:
1200 (If using RSIU TTY port or RMDS,
the Baud rate can be higher than 1200 bps.)
Parity:
Even
Data bits:
7
Stop bits:
1