Upgrade
111
Backup Menu (DKBackup)
14. Press
Enter
and the following screen displays:
15. Press
Enter
(twice) after completing the Steps above. The Baud Rate Selection screen
displays (shown below). This screen enables you to set the DKAdmin/DKBackup PC
COM port baud rate which must match the baud rate of the TTY port set by the
programming telephone in Program 76 (if upgrading TTY port to RSIU).
Note
This Step enables you to switch the TTY port from a PIOU (1200 bps) to an RSIU
(9600 bps) TTY port to complete the upgrade process faster.
Processor Conversion
Step A: After changing the processor, you should initialize the new
processor by running Program 91-9 manually from the Programming
Telephone. Then you must reset the PIOU, PIOUS, RSSU, or RSIU/
RSIS/RMDS TTY port that is connected to DKAdmin PC by performing
Step B and/or C.
Step B: From the Programming Telephone, use Program 03 to set code 41 for
the cabinet slot that contains the new TTY/Maintenance PIOU,
PIOUS, or RSSU PCB and proceed to Step D. If you added an RSIU/
RSIS/RMDS PCB, set code 49 for cabinet slot 11 and proceed to Step
C.
Step C: From the Programming Telephone, use Program 76-1 and 76-2 to set
the RSIU/RSIS/RMDS ports for their appropriate functions and baud
rates. DKAdmin will pull Program 76 and adjust the DKAdmin
customer database accordingly. Make sure the TTY/Maintenance port
settings are correct to insure a successful Upgrade process.
Proceed to Step D.
Step D: Turn DK off (5 sec) then on. From the Programming Telephone, test
the RCTU (R3) RAM by running Program 00-(51,52/61, 62)
Press any key to Continue
Baud Rate Selection
Please adjust the baud rate of DKBackup PC COM port to match the new PIOU,
PIOUS, RSSU or RSIU/RSIS you may have installed.
Baud Rate .............
9600
300
1200
2400
4800
9600
14400
19200
38400
57600