Restore Data

105

Backup Menu (DKBackup)

7. After completing the steps on the screen, press

Enter

(twice) and the Baud Rate

Selection screen displays (shown below). This screen enables you to set the DKAdmin/
DKBackup PC COM port baud rate which must match the baud rate of the TTY or modem
port set by the programming telephone.

8. Select the DKAdmin/DKBackup PC COM port baud rate and press

Enter

. The

information screen below instructs you to pull Program 03 if you changed any PCBs
during the Restore process. DKAdmin/DKBackup enables you to pull Program 03
automatically.

Note

If you are connected to the customer system, always have DKAdmin/DKBackup pull
Program 03 when restoring data. If you are restoring data to an RCTU that is installed
in a test system that is not loaded with the same PCBs as the customer database, do not
pull Program 03 at this time.

DKAdmin/DKBackup will then download Program 03 and Program 76 to ensure a
successful restore process.

Baud Rate Selection

Please adjust the baud rate of DKBackup PC COM port to match the new

PIOU, PIOUS, RSSU or RSIU/RSIS you may have installed.

Baud Rate ...............

9600

Processor Conversion

If you added or changed any PCBs other than the RCTU PCB in the DK system,
the customer database will need to be updated to reflect these changes.
You can pull Program 03 from the DK to accomplish this.

If you pull Program 03 from the DK, you will override the existing
customer database with the DK data.

If you do not pull Program 03 from the DK, the existing customer database
will remain intact.

IMPORTANT: If you have upgraded the customer database offline, DO NOT pull
Program 03 as it will override your changes.

IMPORTANT: Any time DK14/DK16e/DK40 is upgraded, Program 03 must be
pulled so DKAdmin can update the new system’s cabinet drawing.

NOTE: If you pull Program 03 from the DK, the DK will be initialized with
Program 91-1 automatically. This initialization program identifies the
PCBs to the DK.

Press any key to Continue

300

1200

2400

4800

9600

14400

19200

38400

57600