12.4 Checking of the zero pressure control

The zero pressure control is set at the factory. To measure this value you need

a difference pressure gauge with a range of +0,2 to -0,8 mbar (+0.08 to -0.001”

W.C.). Follow the next procedure:

-

Press the MODE-button for 5 seconds.

-

The display will show COdE followed by an arbitrary number;

-

Select by means of the

or the

button the code C123;

- Press the Store-button to confirm the code (code blinks 1 x);

-

Press the MODE-button until SERV is shown;

-

Press the STEP-button once until 1 is shown;

alternately 1 and OFF will be shown.

- Turn the upper measuring nipple on the gas valve open (fig. 19);

- Connect the hose of the digital pressure gauge to the upper measuring nipple of

the gas valve

-

Press the

button until the minimum value is achieved;

The fan will function to its minimum revolutions (burner is active)

-

Measure the negative pressure.

Value should be 0 to -4Pa (0 to -0.04 mbar or 0 to -0.016" W.C.).

-

If the zero pressure deviates too much:

-

Remove black cover of the gas valve

-

Remove cap with Torx screwdriver (fig. 20)

-

Turn slightly the Torx screw behind the cap:

Turn left is positive pressure deviation

Turn right is negative pressure deviation

- Ending this procedure is done by pressing the Reset button.

- Proceed by checking the O

2

value and correct it if necessary.