13

connection diameters

table 2

boiler connections / mounting points

figure 2

f w g k r c

Connection for combustion air supply and vent system

f w g k r c

Boiler type

E75CN

E110CN

E75CP

E110CP

Vent system / Combustion air supply

80/125mm

80/125mm

Gas pipe - g

3/4"M-NPT

3/4"M-NPT

Supply pipe - f

0.87" x 3/4"M-NPT /

22mm

G3/4"x

3/4"M-NPT

Return pipe - r

0.87" x 3/4"M-NPT /

22mm

G3/4"x

3/4"M-NPT

Condensate pipe - c

0.87" / 22mm

0.87" / 22mm

Cold water pipe - k

0.59" x 3/4"M-NPT /

15mm

G1/2"x

3/4"M-NPT

Hot water pipe - w

0.59" x 3/4"M-NPT /

15mm

G1/2"x

3/4"M-NPT

Combi