Outdoor reset, Heat curve day heat curve night – Rinnai E75CN User Manual
Page 48
Installation & Servicing Instructions Rinnai E-Series
48
Service Mode
SERV
VALUE
DESCRIPTION
RANGE
1
OFF
boiler in operation with burner function on
OFF - max.
2
OFF
fan adjustable and burner off
OFF - max.
3
OFF
pump adjustable with burner on
OFF - max.
4
OFF
showroom position ON = active and OFF = non active
ON - OFF
.
.
.
.
Error Mode
ERRO
VALUE
DESCRIPTION
Err.L - Err.5
Last saved error until 5 last previous errors
1
error code
2
operation status boiler
3
°F
supply water temperature T1
4
°F
return water temperature T2
5
kW
load (.. x3415 = .. BTU/hr)
6
%
pump capacity
* Most of the data in this table can be requested by the RS100. Most of the
adjustments which are stated in this table are unnecessary when in combina-
tion with the Rinnai RS100 thermostat and will be taken care of by the RS100
itself and do not have to be adjusted. For further information regarding to the
RS100 thermostat refer to the Rinnai RS100 installation manual.
Parameter-, Info-, Service- and Error-chapters
Table 12
NOTICE
i
heating line adjustments Parameter Step 6 and 7
graph 2
outside temperature in °F
flow water temperature in °F
Outdoor reset
Heat curve day
Heat curve night
230
212
194
176
158
140
122
104
86
68
50
-4.0
-0.4
3.2
6.8
10.4
14.0
17.6
21.2
24.8
28.4
32.0
35.6
39.2
42.8
46.4
50.0
53.6
57.2
60.8
64.4
68.0
2.30
1.50
1.00
1.00
0.50
1.80
2.00
1.75