beautypg.com

Rinnai REU-V2526W-US User Manual

Rinnai Water boiler

background image

2526W SP-1

R70e (2526W)

Type of Appliance

Rinnai model number

Operation

Exhaust system

Minimum/Maximum Gas Rate (Input)

Electrical


Electrical Consumption



Ignition System

Hot Water Capacity

Temperature

Temperature (without remote)

Approved Gas Types

Installation

Energy Factor

Thermal Efficiency

Service Connections



Water Flow Control

Minimum/Maximum Water Supply Pressure

Temperature controlled, continuous flow, gas hot water system

REU-V2526W-US

With or without remote controls, mounted in kitchen, bathroom, etc.

Outdoor forced combustion

15,000 - 199,000 BTU/h (Natural Gas or Propane)

Appliance:

AC 120 Volts - 60 Hz

Remote Control:

DC 12 Volts

Normal

63

watts

Standby 5.5

watts

Anti-frost protection

84 watts

Direct electronic ignition

0.6 to 6.5 GPM (50° F rise)

0.6 to 7.0 GPM (35° F rise)

98° - 140° F

120° F (factory default)

Natural or Propane (ensure unit matches gas type)

Outdoors only

Natural Gas: 0.81

Propane: 0.80

Natural Gas: 84%

Propane: 84%

Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT

Water flow sensor, electronic water control and by-pass control

20 - 150 PSI (50 PSI or above is recommended for maximum flow)

2526W SP-1 4/2007

FLOW TABLE

Water Flow Capacity Curves

(For 1 to 5 units manifolded in parallel)

© 2005 Rinnai Corporation

0.0

5.0

10.0

15.0

20.0

25.0

30.0

35.0

40.0

0

25

50

75

100

125

150

T – Temperature Rise (°F)

H

o

t W

a

te

r

F

lo

w

R

a

te

(

g

p

m

)

1 Unit

2 Units

3 Units

4 Units

5 Units