5 channel unit interface timing, 5 channel unit interface timing, Table 4-7 – Rockwell SoniCrafter BT8960 User Manual
Page 86: Table 4-8

76
4.0 Electrical & Mechanical Specifications
4.5 Channel Unit Interface Timing
Bt8960
Single-Chip 2B1Q Transceiver
N8960DSB
4.5 Channel Unit Interface Timing
Table 4-7. Channel Unit Interface Timing Requirements, Parallel Master Mode
Symbol
Parameter
Minimum
Maximum
Units
14
TQ[1,0] Setup prior to QCLK Falling Edge
100
ns
15
TQ[1,0] Hold after QCLK Low
25
ns
Table 4-8. Channel Unit Interface Switching Characteristics, Parallel Master Mode
Symbol
Parameter
Minimum
Maximum
Units
16
RQ[1,0] Hold after QCLK Rising Edge
–50
ns
17
RQ[1,0] Delay after QCLK High
50
ns
Figure 4-3. Channel Unit Interface Timing, Parallel Master Mode
14
15
16
17
RQ[1,0]
QCLK
TQ[1,0]