beautypg.com

Control module replacement, Backup battery replacement, Maintenance – Regency P40 User Manual

Page 48: Within power module)

background image

Regency

®

P40-1 Direct Vent Gas Fireplace

48

MAINTENANCE

MAINTENANCE

Power Module

3) Remove the Control Module by lifting it up

off of the velcro and pull out.

1) Unplug the power source.

2) Remove the Power Module by lifting it up

off of the velcro and pull out.

Control Module

4) Remove the Heat Shield from the Control

Module by removing the 2 screws.

Heat Shield

5) Unplug all wire harnesses and manual

control box cable plugged into the Control
module.

6) Replace the Control Module and reverse

steps to re-install.

CONTROL MODULE

REPLACEMENT

1) Unplug the power source.

2) Remove the Power Module by lifting it up

off of the velcro and pull out.

Power Module

3) Remove the Power Module cover by

removing the 2 screws, one on each side
of the box.

4) Replace the 9V and AA battery and reverse

steps to re-install.

BACKUP BATTERY

REPLACEMENT

(within Power Module)

NOTE: The 9V battery operates the

rear burner under power outage
conditions.

The AA battery operates the DC
Sparker for lighting the pilot.