P40-1 Direct Vent Gas Fireplace

20

INST

ALLA

TION

INSTALLATION

V

H1

H

V1

V1

V

H

Vertical Venting with Two (2) 90

o

Elbows

Vertical Venting with Three (3) 90

o

Elbows

One 90

o

elbow = Two 45

o

elbows.

One 90

o

elbow = Two 45

o

elbows.

Option V

H

V + V1

A)

0' Min. 2' Max. 1' Min.

B)

1' Min. 4' Max. 2' Min.

C)

2' Min. 5' Max. 3' Min.

D)

3' Min. 6' Max. 4' Min.

E)

4' Min. 7' Max. 5' Min.

F)

5' Min. 8' Max. 6' Min.

With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
8 feet total horizontal.

Please note min. 1 foot
between 90

o

elbows is

required.

For additional vertical venting with 2
x 90

o

elbows, refer to next page.

Option V

H + H1 V + V1

A)

0' Min. 2' Max. 3' Min.

B)

1' Min. 2' Max. 3' Min.

C)

2' Min. 3' Max. 4' Min.

D)

3' Min. 4' Max. 6' Min.

E)

4' Min. 5' Max. 7' Min.

F)

5' Min. 6' Max. 8' Min.

G)

6' Min. 7' Max. 9' Min.

H)

7' Min. 8' Max. 10' Min.

With these options, max.
total pipe length is 30 feet
with min. of 10 feet total
vertical and max. 8 feet
total horizontal.

Please note min. 1 foot
between 90

o

elbows is

required.

VENT RESTRICTOR SETTING:
When total vertical exceeds total horizontal by 2x the vent restrictor
setting is set to 1.

VENT RESTRICTOR SETTING:
When total vertical exceeds total horizontal by 3x the vent
restrictor setting is set to 1.