Operating instructions, First fire, Operation during power outage – Regency P40 User Manual

Page 41: Opera tion

background image

Regency

®

P40-1 Direct Vent Gas Fireplace

41

OPERA

TION

OPERATING INSTRUCTIONS

During the fi rst few fi res, a white fi lm
may develop on the glass front as part of
the curing process. The glass should be
cleaned after the unit has cooled down
or the fi lm will bake on and become very
diffi cult to remove. Use a non-abrasive
cleaner and DO NOT ATTEMPT TO CLEAN
THE GLASS WHILE IT IS HOT.

The FIRST FIRE in your heater is part of the
paint curing process. To ensure that the paint
is properly cured, it is recommended that you
burn your fi replace for at least four (4) hours the
fi rst time you use it with the fan on.

When fi rst operated, the unit will release an
odour caused by the curing of the paint and the
burning off of any oils remaining from manufac-
turing. Smoke detectors in the house may go off
at this time. Open a few windows to ventilate
the room for a couple of hours. The glass may
require cleaning.

NOTE: The main burner will always start on

"HIGH" and resume it's last setting after
20 seconds of operation.

NOTE: When the glass is cold and the appliance

is lit, it may cause condensation and fog
the glass. This condensation is normal
and will disappear in a few minutes as
the glass heats up.

DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS STILL HOT
!

FIRST FIRE

DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.

OPERATION DURING

POWER OUTAGE

Important:
If the unit is not used for a prolonged period of
time, we recommend turning the 3-way switch
on the manual control panel to "Off". Also see
"Lighting Plate Instructions" for details on how to
turn off the pilot.

NOTE: The fan will not operate during a

power

outage.

Rear Burner

Switch

3-way Switch

Manual Control Panel

When in "Remote" position;
In the event of a power failure, if the 3-way switch
is in the "Remote" position, the unit cannot be
operated with the Remote Control until after
power is restored.

To operate unit during a power failure;

NOTE: Both burners when on will operate at the

lowest fl ame setting. The BTU's for NG
will be 13,000 and 12,000 for LP.

Front Burner Operation:
1) Open the bottom louver to gain access to

the Manual Control Panel.

2) To turn on the front burner, change the 3-way

switch to "Manual" position.

Rear Burner Operation:
1) Open the bottom louver to gain access to

the Manual Control Panel.

2) To turn on the rear burner, change the Rear

Burner Switch to the "On" position. Changing
the switch to the "Off" postion will turn the
rear burner off.

Note: The rear burner will only operate if the
front burner is on.

When in "Manual" position;
In the event of a power failure, if the 3-way switch
is in the "Manual" position the front buner will
remain on at the lowest setting and will remain
on when power resumes. If the rear burner is
not in use, to operate see "Rear Burner Opera-
tion" above.

Both burners when on will operate at the lowest
fl ame setting. The BTU's for NG will be 13,000
and 12,000 for LP.

When power resumes the unit will remain on at
the lowest setting until reset using the remote
control.

NOTE: When power is restored, reset the

3-way switch on the Manual Control
Panel to the "Remote" position to be
able to use the FireWizard

TM

Remote

Control.