Regency e33 sunrise gas insert warning, Minimum fireplace dimensions, Lm j k n

background image

L

M

J

K

N

Model

E33S-NG1

E33S-LP1

Fuel Type

Natural Gas

Propane

Minimum Supply Pressure

5” W.C. (1.25 kPa)

12” W.C. (2.99 kPa)

Manifold Pressure - High

3.8” W.C. (0.95 kPa)

11” W.C. (2.74 kPa)

Manifold Pressure - Low

1.1” W.C. (0.27 kPa)

2.9” W.C. (0.72 kPa)

Orifice Size -

Altitude 0-4500 ft.

#42 DMS

#54 DMS

Minimum Input

Altitude 0-4500 ft. (0-1372m)

13,500 BTU/h

(3.95 kW)

12,000 BTU/h

(3.51 kW)

Maximum Input

Altitude 0-4500 ft. (0-1372m)

26,000 BTU/h

(7.61 kW)

23,000 BTU/h

(6.74 kW)

Vent Sizing

3” Co-linear

3” Co-linear

Minimum Fireplace Dimensions

The minimum fireplace dimensions for the FPI gas fireplace insert are

shown in the following diagrams:

Dimension Description

E33S

J

Height

24-3/16” (614mm)

K

Width

32-1/4” (819mm)

L

Depth

16-3/4” (426mm)

M

Max. Lintel Bar Depth

8” (203mm)

N

Rear Width

25” (635mm)

Dimension Description

E33S

A

Faceplate Width

46-3/4” (1187mm)

B

Faceplate Height

30-5/8” (778mm)

C

Unit Width

32-1/8” (816mm)

D

Unit Height

23-3/4” (603mm)

E

Unit Depth

16-1/2” (419mm)

F

Faceplate to Vent Centerline

11-3/8” (290mm)

G

Faceplate Depth

1-1/8” (28mm)

H

Height to Vent Collar

22-7/8” (581mm)

I

Faceplate Depth

2-7/8” (72mm)

Approved Venting Systems

Flex Vent Systems:

FPI AstroCap™ Flex Vent

Regency E33 Sunrise Gas Insert

WARNING

Failure to maintain required clearances is a major cause of chimney related fires.

Installation of this fireplace must comply with these clearances

Please note: Due to ongoing product development, product appearance and specifications

are subject to change without notice.

This manual is intended to be a Sales Reference Guide only.

Do NOT use for actual framing and installation of any unit.

Some specifications may change without notice.

You must use the actual manual for exact installation specifications.

E33S Sunrise Gas Insert