INST

ALLA

TION

INSTALLATION

14)

Re-install pilot shield.

15)

Set aeration on both front and rear burner
for LP gas;

Rear

1/4"

Front

1/8"

16)

Reverse steps 8 to 4.

17)

Remove the Power Module by lifting it up off

of the velcro and move it over to the side.

Power Module

Control Module

18)

Remove the Control Module, located behind

the power module, by lifting it up off of the
velcro.

19)

Place the J9 jumper using needle nose

pliers, located under the heat shield.

20)

Reverse steps 18 to 17. Be careful not to

pinch wires.

21)

Remove the 2 wires connected to the

modulating

coil.

Modulating Coil

22)

Using a Torx T20, or slotted screwdriver,
remove and discard the three pressure
regulator mounting screws and rubber
diaphram.

23)

Insure that the new rubber gasket is

properly positioned and install the new
modulating pressure regulator assembly
to the valve using the screws supplied
with the kit. Tighten screws securely.

24)

Reattach 2 wires to modulating coil.

25)

Install the enclosed identifi cation label

to the valve body where it can be easily
seen. The label is found in the coil pack-
age.

26)

Attach the LP conversion decal near or

on top of the serial # decal located on a
metal plate under the unit.

30)

Check inlet (5" wc) and outlet (3.5" wc)

pressures.

31)

Check operation of fl ame control using

the manual control box located on the
right side under the fi rebox.

32)

Re-install logs and fl ush door. Check for

proper fl ame appearance and glow on
logs.

WARNING!

This conversion kit should be installed
by a qualifi ed service agency in ac-
cordance with the authority having
jurisdiction. If the information in these
instructions are not followed exactly, a
fi re, explosion or production of carbon
monoxide may result causing property
damage, personal injury or loss of life.
The qualifi ed service agency is respon-
sible for the proper installation of this
kit. The installation is not proper and
complete until the operation of the con-
verted appliance is checked as speci-
fi ed in the manufacturer's instructions
supplied with the kit.

Installer Notice:

These instructions must be left

with the appliance.

J9 Jumper Location

J9 Jumper

27)

Replace the red "Propane" label with the
yellow "Natural Gas" label on the valve
assembly.

28)

Ensure proper installation of venting is
complete, gas line is connected and then
turn on power to unit.

29)

Check for gas leaks.