Regency Gas Insert U35-LP1 User Manual
Gas inserts, U35 gas insert, Minimum fireplace dimensions
A
C
B
D
H
I
F
E
U35 Gas Insert
Model
U35-NG1
U35-LP1
Fuel Type
Natural Gas
Propane
Minimum Supply Pressure
5” W.C. (1.25 kPa)
12” W.C. (2.99 kPa)
Manifold Pressure - High
3.8” W.C. (0.95 kPa)
11” W.C. (2.74 kPa)
Manifold Pressure - Low
1.1” W.C. (0.27 kPa)
2.9” W.C. (0.72 kPa)
Orifi ce Size -Altitude 0-4500 ft.
#33 DMS
#50 DMS
Minimum Input
Altitude 0-4500 ft. (0-1372m)
17,500 BTU/h
(5.13 kW)
17,500 BTU/h
(5.13 kW)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
35,000 BTU/h
(10.26 kW)
35,000 BTU/h
(10.26 kW)
Vent Sizing
3” Co-linear
3” Co-linear
Minimum Fireplace Dimensions
The minimum fi replace dimensions for the FPI gas fi replace insert are
shown in the following diagrams:
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
L
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
M
J
K
N
Dimension Description
Contour
Faceplate
Molded
Faceplate /
Palace Font
J
Height
25” (635mm)
26-3/4” (679mm)
K
Width
32-1/4” (819mm)
34-1/2” (876mm)
L
Depth
17” (432mm)
18” (457mm)
M
Max. Lintel Bar Depth
9” (229mm)
10” (254mm)
N
Rear Width
25” (635mm)
25” (635mm)
U35 Gas Insert
Dimension Description
U35
A
Faceplate Width
45-9/16” (1157mm)
B
Faceplate Height
31-1/8” (791mm)
C
Unit Width
32-1/4” (819mm)
D
Unit Height
24” (610mm)
E
Unit Depth
16-1/8” (410mm)
F
Faceplate to Vent Centerline
9-7/8” (251mm)
G
Faceplate Depth
1-3/8” (35mm)
H
Height to Vent Collar
25 1/2” (648mm)
I
Optional or Standard Front Depth
3-3/4” (95mm)
Approved Venting Systems
Flex Vent Systems:
FPI AstroCap™ Flex Vent
129
August 2008 Product Specifi cations Book
Gas Inserts