Page 11: Inst alla tion

background image

Regency

®

P40-1 Direct Vent Gas Fireplace

11

INST

ALLA

TION

INSTALLATION

10-1/4” Above Fireplace

6”

6”

Diagram 1

1) Frame in the enclosure for the unit with framing material. The framed

opening for the assembled kit is 42-1/2" high x 40-1/2" wide x 20-1/16"
deep (1080mm H x 1029mm W x 508mm D), see Diagram 1. Also
see Diagram 2 for corner installations.

Note: When constructing the framed opening, please ensure there

is access to install the gas lines when the unit is installed.
See diagram 3 for details.

2) For exterior walls, insulate the enclosure to the same degree as the

rest of the house, apply vapour barrier and drywall, as per local instal-
lation codes. (Do not insulate the fi replace itself.)

3) The unit does not have to be completely enclosed in a chase. A non-

combustible header must be used. You must maintain clearances
from the vent to combustible materials: See "Clearances" section.
Combustible materials can be laid against the side and back standoffs
and the stove base.

FRAMING & FINISHING

42-1/2"

(1080mm)

40-1/2”

(1029mm)

Min. 20-1/16"

(508mm)

Non-Combustible

Header

(On Edge)

Non-Combustible Studs

(when installing the full screen front only)

The HeatWave Duct Kit has different
clearance and framing requirements,
check the HeatWave manual for details.

Diagram 2

Diagram 3

Note: Height is from the base of the unit. Take into consideration

the hearth height and material.

Height = 42-1/2" plus height of hearth.

WARNING: When installing the Full Screen Doors

The Full Screen Front requires additional non combustible facing and
non-combustible framing. Ensure the 10-1/4" above the fi replace, 6"
on both sides and both the header and side studs are non-combustible
materials. All other clearances, including mantel, remain the same.

WARNING: When installing the

Full Screen Doors

The Full Screen Front requires
additional non combustible facing
and non-combustible framing.
Ensure the 10-1/4" above the
fi replace, 6" on both sides and
both the header and side studs
are non-combustible materials.
All other clearances, including
mantel, remain the same.

FULL SCREEN DOOR

FACING REQUIREMENTS