Perform Channel Configuration:
Paragon recognizes a HubPac as an extension of a CIM, rather than as a device. As a result, each
server connected to the HubPac is configured as a directly connected server would be.
1. On the Selection Menu (by channel ID number) each green line indicates an active channel

(CIM/computer). Highlight the CIM/server to be selected by using the <Ç> and <È> or the
<Page Up> and <Page Down> keys, then press <Enter>.

2. Normal computer access indicates successful connection. If necessary, adjust the computer’s

video quality by keying on <+> or <> while in Hot Key mode.

3. Enter a meaningful name for each server (channel).

a.

Press <F5> for the Administration Menu and select the Channel Configuration submenu.

b.

On the Channel Configuration Menu, press the <Ç> or <È> keys to highlight the Name field
for channel ID where CIM/computer was just installed.

c.

Press <Enter> - the highlight will turn blue.

d.

Edit Name and press <Enter> when finished - the highlight will turn green as you begin to
type.

e.

Press <S> to save the new name.

f.

Press <F2> to return to the Selection Menu and verify that the new name appears on the
Selection Menu in green.

4. Repeat for each CIM/server desired (up to 32).