beautypg.com

Table 35 cwdm gbic specifications, Table 36 cwdm gbic optical specifications – Nortel Networks 1000BASE-SX User Manual

Page 70

background image

70

GBIC specifications

Table 35
CWDM GBIC specifications

Parameter

Specifications

Connectors

SC

Cabling

SMF, 9 µm

Data rate

0.0125 to 1.25 Gbit/s

Total system budget
@ 1.25 Gbit/s
BER < 10

-9

w/PRBS 2

7

-1

30 dB — Total system budget is defined as P

out

- P

in

- typical

connector losses.

Data format

Electrical 8B/10B; optical 64B/66B

Operating temperature
(case temperature)

0 to 70C

Storage temperature

-10 to 85C

Distance

Up to 120 km

The following table describes CWDM GBIC optical characteristics. In this
table, the center wavelength range "x" is 1470, 1490, 1510, 1530, 1550,
1570, 1590, or 1610 nm.

Table 36
CWDM GBIC optical specifications

Parameter

Symbol

Minimum

Typical

Maximum

Transmitter center wavelength range
(nm) for a case temperature of 0 to
70C

λ

c

(x-4)

(x+1)

(x+7)

Transmitter center wavelength range
(nm) for a case temperature of 0 to
60C

λ

c

(x-4)

(x+1)

(x+6)

Wavelength temperature
dependence

0.08 nm/C

Side mode suppression ratio

SMSR

30 dB

Transmitter optical output power
(average power coupled into single
mode fiber)

P

out

+2.0 dBm

+6.0 dBm

Transmitter extinction ratio

OMI

9 dB

Transmitter eye opening (conforms
with IEEE 802.3 and Fibre Channel
Eye Masks)

60%

Optical return loss

ORL

14 dB

Input wavelength

λ

in

1450 nm

1620 nm

Nortel Metro Ethernet Routing Switch 8600

Installation — SFP, XFP, GBIC, and OADM Hardware Components

NN46220-301

01.01

Standard

5.0

1 May 2008

Copyright © 2008, Nortel Networks

.

This manual is related to the following products: