1000base-sx gbic specifications, Table 30 1000base-t gbic specifications – Nortel Networks 1000BASE-SX User Manual
Page 65
1000BASE-SX GBIC specifications
65
ATTENTION
You must disable autonegotiation before operating the 1000BASE-T GBIC.
By default, GBICs inserted into certain product-specific modules are set
for Autonegotiation = True. If autonegotiation does not work initially, Nortel
recommends that you reconfigure the switch to use a fixed-speed setting of 1000
Mbit/s, full-duplex, on both sides.
The maximum current requirement of the GBIC is 375 milliamperes (mA) at
5 volts (V).
The following table describes the 1000BASE-T GBIC.
Table 30
1000BASE-T GBIC specifications
Parameter
Specifications
Standards
IEEE 802.3z, IEEE 802.3ab
Connectors
RJ-45
Cabling
CAT5 unshielded twisted pair (UTP)
Distance
Up to 100 m
1000BASE-SX GBIC specifications
The 1000BASE-SX GBIC provides 1000BASE-SX Gigabit Ethernet
connectivity using SC duplex multimode fiber connectors. This GBIC
supports full-duplex operation only. The part number of this GBIC is
AA1419001-E5.
The following table describes standards, connectors, cabling, and distance
for the 1000BASE-SX GBIC.
CAUTION
When multimode fiber is used in long-distance applications,
external, removable, mode-conditioning patch cords may be
required to prevent differential mode delay (DMD). Excessive DMD
can cause an increase in the bit error rate (BER). You can order
mode conditioning patch cords through Nortel:
•
SC-SC Mode-Conditioning Patch Cord 62.5/125 (part
number AA0018035)
•
SC-SC Mode-Conditioning Patch Cord 50/125 (part
number AA0018036)
Nortel Metro Ethernet Routing Switch 8600
Installation — SFP, XFP, GBIC, and OADM Hardware Components
NN46220-301
01.01
Standard
5.0
1 May 2008
Copyright © 2008, Nortel Networks
.