beautypg.com

Installing an xfp – Nortel Networks 1000BASE-SX User Manual

Page 37

background image

Installing an XFP

37

Model number

Product number

Description

NTK587AY-E5

1537.40

NTK587BA-E5

1538.19

NTK587BC-E5

1538.98

NTK587BE-E5

1539.77

NTK587BG-E5

1540.56

NTK587BJ-E5

1541.35

NTK587BL-E5

1542.14

NTK587BN-E5

1542.94

NTK587BQ-E5

1543.73

NTK587BS-E5

1544.53

10GBASE DWDM

NTK587BU-E5

1545.32

Note: Due to hexidecimal to decimal rounding, and vice-versa, the wavelength numbers provided
by the XFP manufacturer and reported by the Metro Ethernet Routing Switch 8600 system may
vary slightly.

Installing an XFP

Install an XFP to provide a 10 Gigabit Ethernet interface between the switch
and other network devices.

Installing an XFP takes about 3 minutes.

Prerequisites

Verify that the XFP is the correct model for your network configuration.

Procedure steps

CAUTION

Nortel recommends that you install only one 10GBASE-ZR/ZW
per module due to cooling limitations on the 8683XLR and
8683XZR modules. Nortel further recommends the installation of
the XFP only in port 1. You can install a 10GBASE-SR, -LR/LW, or
-ER/EW in one or both of the remaining ports.

CAUTION

XFPs are keyed to prevent incorrect insertion. If the XFP resists
pressure, do not force it; turn it over, and reinsert it.

Nortel Metro Ethernet Routing Switch 8600

Installation — SFP, XFP, GBIC, and OADM Hardware Components

NN46220-301

01.01

Standard

5.0

1 May 2008

Copyright © 2008, Nortel Networks

.