Caution – Nortel Networks 1000BASE-SX User Manual
Page 60
60
SFP specifications
You can use 1000BASE-BX SFPs to double the number of your fiber links.
For example, if you have 20 installed fiber pairs with 20 conventional ports
connected, you can use 1000BASE-BX SFPs to expand to 40 ports, using
the same fiber.
The long wavelength optical transceivers used in these models provide
variable distance ranges using single mode fiber optic cabling.
The following table describes standards, connectors, cabling, and distances
for the 1000BASE-BX SFP.
CAUTION
Connect 1000BASE-BX SFP AA1419076-E6 to 1000BASE-BX
SFP AA1419077-E6 using a single mode fiber with at least 6 dB
of attenuation. Damage can result if insufficient attenuation is
provided or if the same 1000-BASE-BX SFPs are connected.
Table 27
IEEE 802.3ah 1000BASE-BX10 SFP specifications
Parameter
Specifications
Connectors
Single-fiber LC
Data rate
1.0 Gbit/s
Line rate (8B/10B code)
1.25 Gbit/s
Distance
AA1419069-E6 and AA1419070-E6: Up to 10 km
AA1419076-E6 and AA1419077-E6: Up to 40
km with SMF
Wavelength
1310 nm and 1490 nm
Link optical power budget
AA1419069-E6 and AA1419070-E6: 11.0 dB
AA1419076-E6 and AA1419077-E6: 20.0 dB
Maximum transmitter and dispersion power
penalty
3.3 dB
Transmitter characteristics
Maximum launch power
AA1419069-E6 and AA1419070-E6: -3.0 dBm
AA1419076-E6 and AA1419077-E6: 3.0 dBm
Minimum launch power
AA1419069-E6 and AA1419070-E6: -9.0 dBm
AA1419076-E6 and AA1419077-E6: -3.0 dBm
Receiver characteristics
Maximum receiver sensitivity
AA1419069-E6 and AA1419070-E6: -19.5 dBm
AA1419076-E6 and AA1419077-E6: -23.0 dBm
Maximum input power (maximum average
receive power)
-3.0 dBm
Nortel Metro Ethernet Routing Switch 8600
Installation — SFP, XFP, GBIC, and OADM Hardware Components
NN46220-301
01.01
Standard
5.0
1 May 2008
Copyright © 2008, Nortel Networks
.