SFP specifications

You can use 1000BASE-BX SFPs to double the number of your fiber links.
For example, if you have 20 installed fiber pairs with 20 conventional ports
connected, you can use 1000BASE-BX SFPs to expand to 40 ports, using
the same fiber.

The long wavelength optical transceivers used in these models provide
variable distance ranges using single mode fiber optic cabling.

The following table describes standards, connectors, cabling, and distances
for the 1000BASE-BX SFP.

CAUTION

Connect 1000BASE-BX SFP AA1419076-E6 to 1000BASE-BX
SFP AA1419077-E6 using a single mode fiber with at least 6 dB
of attenuation. Damage can result if insufficient attenuation is
provided or if the same 1000-BASE-BX SFPs are connected.

Table 27
IEEE 802.3ah 1000BASE-BX10 SFP specifications

Parameter

Specifications

Connectors

Single-fiber LC

Data rate

1.0 Gbit/s

Line rate (8B/10B code)

1.25 Gbit/s

Distance

AA1419069-E6 and AA1419070-E6: Up to 10 km
AA1419076-E6 and AA1419077-E6: Up to 40
km with SMF

Wavelength

1310 nm and 1490 nm

Link optical power budget

AA1419069-E6 and AA1419070-E6: 11.0 dB
AA1419076-E6 and AA1419077-E6: 20.0 dB

Maximum transmitter and dispersion power
penalty

3.3 dB

Transmitter characteristics

Maximum launch power

AA1419069-E6 and AA1419070-E6: -3.0 dBm
AA1419076-E6 and AA1419077-E6: 3.0 dBm

Minimum launch power

AA1419069-E6 and AA1419070-E6: -9.0 dBm
AA1419076-E6 and AA1419077-E6: -3.0 dBm

Receiver characteristics

Maximum receiver sensitivity

AA1419069-E6 and AA1419070-E6: -19.5 dBm
AA1419076-E6 and AA1419077-E6: -23.0 dBm

Maximum input power (maximum average
receive power)

-3.0 dBm

Nortel Metro Ethernet Routing Switch 8600

Installation — SFP, XFP, GBIC, and OADM Hardware Components

NN46220-301

01.01

Standard

5.0

1 May 2008

Copyright © 2008, Nortel Networks

.