NEC Express 320Lc-R User Manual
Page 84

4-40 Windows Setup
3. When RDR is successfully configured, the following two pop-up messages appear.
On the “Warning” pop-up, click [OK], and on the “System Restart Warning” pop-up, click
[Yes].
IMPORTANT:
Clicking [Yes] on the “System Restart Warning” pop-up will restart the system in 2
minutes.
If the pop-up appears multiple times, follow the instruction to restart the system.
4. The following pop-up appears, and the system will be restarted in two minutes:
5. After the system is restarted, mount a disk to set dual disk configuration in Slot 1 of the PCI
module (Group 2).
IMPORTANT:
Mount a new or physically formatted disk which has the same capacity as the mirrored
disk (disk in Slot1 of PCI module (Group1)). (About formatting disks physically, see
“System Configuration” – “SCSI BIOS~Fast!UTIL~” in the separate volume of User’s
Guide to perform “Low-Level Format” on the SCSI Disk Utility.)