beautypg.com

NEC Express 320Lc-R User Manual

Page 76

background image

4-32 Windows Setup

[Team #1: Adaptive Fault Tolerance Mode] is added to Network Component Tree.

4. Select [Stratus emb-82559 10/100 Enet Adapter] from Network Component Tree. The

pop-up menu appears. Select [Team #1: Adaptive Fault Tolerance Mode] from [Add to
Team], and add the adapters.

You will see the warning message when you add the team. You can ignore this warning
message by clicking [OK]. This warning message is to inform you that only one adapter is
added to the team.

5. Select [Stratus emb-82559 10/100 Enet Adapter #2] from Network Component Tree in the

same manner as for 4. The pop-up menu appears. Select [Team #1: Adaptive Fault
Tolerance Mode] from [Add to Team], and add the adapters.

IMPORTANT:

Do not set [Preferred Primary] or [Preferred Secondary] to each

adapter.

6. Make settings of dual configuration for "Stratus emb-82544GC Copper Gigabit Adapter"

(1000Base) as well.

Perform 3 to 5 in the same manner, replacing [Stratus emb-82559 10/100 Enet Adapter]
with [Stratus emb-82544GC Copper Gigabit Adapter].

In 3, you can also select [Load Balancing]. In this case, [Team #X: Adaptive Load
Balancing Mode] will be added.

This manual is related to the following products: