Srg50 and bcm50 features comparison – Nortel Networks SRG50 User Manual
Page 18
![background image](/manuals/192866/18/background.png)
18
Chapter 2 SRG50 overview
NN40140-500
NN40140-500
To reboot the system
1
In Element Manager, navigate to the Reset panel (Administration > Utilities > Reset).
2
Click Reboot BCM50 System.
To verify that the SRG has been successfully created
1
In Element Manager, navigate to the Keycodes panel (Configuration > System > Keycodes).
In the Feature licenses table, verify that the status of the SRG keycode is ACTIVE.
2
Open the Resources folder (Configuration > Resources).
Verify that there is a Survivable Remote Gateway panel.
SRG50 and BCM50 features comparison
The table
on page 18 compares SRG50 and BCM50 features.
Table 5 Comparison of BCM50 and SRG50 (Sheet 1 of 2)
Item
BCM50
SRG50
MBMs
See the
Installation and
Maintenance
Guide
(NN40020-302)
Recommended:
ASM8+ (8 port Analog Station Module); DTM
(Digital Trunk Module - 24 lines on either T1
or E1 or PRI); BRI (4 line BRI S/T Module);
GATM4 (Global Analog Trunk MBM - 4 port);
GATM8 (Global Analog Trunk MBM - 8 port)
ADID4 (4 analog lines)
ADID8 (8 analog lines)
G4x16 (16 digital ports and 4 analog trunks);
G8x16 (16 digital ports and 8 analog trunks)
Supported for ATA connections:
DSM16 (Digital Station Module - 16 ports);
DSM32 (Digital Station Module - 32 ports);
4x16 Combo (16 digital ports, 4 analog
trunks and 1 analog station);
Does not support:
DDIM (Digital Drop and Insert Mux)
FEM (Fiber Expansion Module)
DECT (Digital Enhanced Cordless
Telecommunications)
Digital telephone sets
Yes
No
FCAPS
Yes
Yes, extended to include SRG-specific
alarms and keycodes
Network Configuration Manager
Yes
Yes
Telset Administration
Yes
No
CS 1000 Geographic Redundancy
N/A
Yes
CS 1000 Network Bandwidth Management
N/A
Yes