Table 5-2.
Network Interface LED
Label
Indication
Color
What It Means
OK
Operational
Status
Green
ON
– The interchange circuits for the
interface are in the correct state to
transmit and receive data.
OFF – A Loss of Signal (LOS) condition has
been detected on the leased line
network interface when it is not
transmitting INFO3 or receiving INFO4.
Table 5-3.
User Data Port LED
Label
Indication
Color
What It Means
OK
Operational
Status
Green
ON
– The interchange circuits for the port
are in the correct state to transmit and
receive data.
OFF – The port is idle. Occurs if the port is
configured to monitor DTR and/or RTS
and the lead(s) is not asserted.
Control Lead Descriptions
See Table 5-2,
, for a description of this lead. See
, to interpret the user data port OK control lead.
The LED descriptions and control lead descriptions are the same.
In addition to the OK LED for the user data port, additional control leads can be
monitored through the Display LEDs and Control Leads screen. These indicators
show the current state of each control lead and what they indicate when they are
highlighted; that is, in the On state. These are described in Table 5-4.
Table 5-4.
Additional User Data Port Control Leads
Label
Indication
What It Means
TXD
Transmit Data
Data is being sent to the far-end device.
RXD
Receive Data
Data is being received from the far-end device.
DTR
Data Terminal Ready
The Data Terminal Equipment (DTE) is not
ready to operate.
RTS
Request to Send
The DTE has indicated that it is ready to
transmit data.