beautypg.com

Control lead descriptions, Table 5-2, Table 5-3 – Paradyne FrameSaver SLV 9664 User Manual

Page 99

background image

Operation and Maintenance

5-5

9664-A2-GB20-00

March 2000

Table 5-2.

Network Interface LED

Label

Indication

Color

What It Means

OK

Operational
Status

Green

ON

– The interchange circuits for the

interface are in the correct state to
transmit and receive data.

OFF – A Loss of Signal (LOS) condition has

been detected on the leased line
network interface when it is not
transmitting INFO3 or receiving INFO4.

Table 5-3.

User Data Port LED

Label

Indication

Color

What It Means

OK

Operational
Status

Green

ON

– The interchange circuits for the port

are in the correct state to transmit and
receive data.

OFF – The port is idle. Occurs if the port is

configured to monitor DTR and/or RTS
and the lead(s) is not asserted.

Control Lead Descriptions

See Table 5-2,

Network Interface LED

, for a description of this lead. See

Table 5-3,

User Data Port LED

, to interpret the user data port OK control lead.

The LED descriptions and control lead descriptions are the same.

In addition to the OK LED for the user data port, additional control leads can be
monitored through the Display LEDs and Control Leads screen. These indicators
show the current state of each control lead and what they indicate when they are
highlighted; that is, in the On state. These are described in Table 5-4.

Table 5-4.

Additional User Data Port Control Leads

Label

Indication

What It Means

TXD

Transmit Data

Data is being sent to the far-end device.

RXD

Receive Data

Data is being received from the far-end device.

DTR

Data Terminal Ready

The Data Terminal Equipment (DTE) is not
ready to operate.

RTS

Request to Send

The DTE has indicated that it is ready to
transmit data.