Alarms – Paradyne FrameSaver SLV 9664 User Manual
Page 137
Troubleshooting
6-7
9664-A2-GB20-00
March 2000
Alarms
The following table describes the alarm conditions that will generate an SNMP
trap for a physical interface, and the frame relay LMIs and DLCIs. These alarm
conditions also generate Health and Status messages seen on the System and
Test Status screen.
Main Menu
→
Status
→
System and Test Status
Table 6-1.
Alarm Conditions (1 of 3)
Alarm Condition
What It Indicates
What To Do
CTS down to
Port-1
Device
The CTS control lead on
the device’s interface is off.
Check DTR and RTS from
Port-1.
H
Verify that the port is enabled.
H
Check DTR from the user data
port.
DLCI
nnnn Down,
frame relay link
1, 2
The DLCI for the specified
frame relay link is down.
Verify that the network LMI is up.
If it is, contact your network
service provider.
DTR down from Port-1
Device
The DTR control lead on
the device connected to
Port
-n is disasserted.
Examine the attached DTE and
cable connected to the
FrameSaver unit’s port.
H
Check that the Port
-1 cable is
securely attached at both
ends.
H
Check the status of the
attached equipment.
1
nnnn indicates a DLCI number of 16 through 1007.
2
frame relay link is one of the following:
– Net1-FR1. The frame relay link specified for the network data port, Network 1.
– Port-1. The frame relay link associated with the user data port.