Troubleshooting

6-7

9664-A2-GB20-00

March 2000

Alarms

The following table describes the alarm conditions that will generate an SNMP
trap for a physical interface, and the frame relay LMIs and DLCIs. These alarm
conditions also generate Health and Status messages seen on the System and
Test Status screen.

Main Menu

Status

System and Test Status

Table 6-1.

Alarm Conditions (1 of 3)

Alarm Condition

What It Indicates

What To Do

CTS down to
Port-1

Device

The CTS control lead on
the device’s interface is off.

Check DTR and RTS from
Port-1.

H

Verify that the port is enabled.

H

Check DTR from the user data
port.

DLCI

nnnn Down,

frame relay link

1, 2

The DLCI for the specified
frame relay link is down.

Verify that the network LMI is up.
If it is, contact your network
service provider.

DTR down from Port-1
Device

The DTR control lead on
the device connected to
Port

-n is disasserted.

Examine the attached DTE and
cable connected to the
FrameSaver unit’s port.

H

Check that the Port

-1 cable is

securely attached at both
ends.

H

Check the status of the
attached equipment.

1

nnnn indicates a DLCI number of 16 through 1007.

2

frame relay link is one of the following:

– Net1-FR1. The frame relay link specified for the network data port, Network 1.

– Port-1. The frame relay link associated with the user data port.