Troubleshooting

6-9

9664-A2-GB20-00

March 2000

Table 6-1.

Alarm Conditions (3 of 3)

Alarm Condition

What To Do

What It Indicates

Network Com Link
Down

The communication link for
the COM port is down and
the COM port is configured
for Net Link.

Check the router connected to
the COM port.

Self-Test Failure

The unit did not pass its
basic verification tests
when it was powered on or
reset.

H

Reset the unit.

H

Contact your service
representative.

SLV Timeout,
DLCI

nnnn,

frame relay link

1, 2

An excessive number of
SLV communication
responses from the remote
system have been missed
on the specified multiplexed
DLCI and link.

When a hardware bypass-
capable device has been
detected at the other end of
the PVC and this condition
occurs, only user data for
EDLCI 0 will be transmitted
as long as the condition
exists.

Verify that the network LMI is up.
If it is, contact your network
service provider.

1

nnnn indicates a DLCI number of 16 through 1007.

2

frame relay link is one of the following:

– Net1-FR1. The frame relay link specified for the network data port, Network 1.

– Port-1. The frame relay link associated with the user data port.