Operation and Maintenance

5-7

9664-A2-GB20-00

March 2000

Table 5-5.

Device Messages (2 of 5)

Message

What To Do

What It Indicates

File Transfer Failed –
Invalid file

(Seen at an FTP
terminal.)

A file transfer was
attempted, but it was not
successful.

H

Try again, making sure you
type the filename correctly.

H

Exit the FTP session, or
download another file.

See

Changing Software

.

Invalid Character (

x )

A non-valid printable ASCII
character has been
entered.

Reenter information using valid
characters.

Invalid date: must be
mm/dd/yyyy

A non-valid date was
entered on the System
Information screen.

Reenter the date in the
month/day/4-digit year format.

Invalid date and/or
time

A non-valid date or time
was entered on the System
Information screen. The
date does not exist (e.g.,
February 30th).

Reenter the date in the
month/day/4-digit year format
and/or time in the
hour:minutes:seconds format.

Invalid time: must be
hh:mm:ss

A non-valid system time
was entered on the System
Information screen.

Reenter the time in the
hour:minutes:seconds format.

Invalid – Already
Active

A test was already in
progress when it was
selected.

No action needed.

Invalid Password

Login is required and an
incorrect password was
entered; access is denied.

H

Try again.

H

Contact your system
administrator to verify your
password.

Invalid Test
Combination

A conflicting loopback or
pattern test was in progress
when Start was selected to
start another test, or was
active on the same or
another interface when
Start was selected.

H

Wait until other test ends and
message clears.

H

Cancel all tests from the Test
screen ( Path: main/ test ).

H

Stop the test from the same
screen the test was started
from.

Limit of six Login IDs
reached

An attempt to enter a new
login ID was made, and the
limit of six login/password
combinations has been
reached.

H

Delete another login/password
combination.

H

Reenter the new login ID.

Limit of Mgmt PVCs
reached

New was selected from the
PVC Connection Table and
the maximum number of
management PVCs has
already been created.

H

Do not create the
management PVC.

H

Delete another management
PVC, and try again.