beautypg.com

Configuring general system options, Able 3-3, General system options – Paradyne FrameSaver SLV 9664 User Manual

Page 50: General

background image

Configuration

3-22

9664-A2-GB20-00

March 2000

Configuring General System Options

Select General from the System menu to configure the general system
configuration options (see Table 3-3).

Main Menu

Configuration

System

General

Table 3-3.

General System Options

Test Timeout

Possible Settings: Enable, Disable
Default Setting: Enable

Determines whether or not loopback and pattern tests have a duration after which they
are terminated automatically.

Enable – All Loopback and Pattern tests have a timeout. This setting is recommended
when the FrameSaver unit is managed remotely through an in-band data stream. If the
FrameSaver unit is accidently commanded to execute a disruptive test on the interface
providing the management access, control can be regained after the timeout expires,
terminating the test.

Disable – Loopback and pattern tests must be manually terminated.

Test Duration (min)

Possible Settings: 1 – 120
Default Setting: 10

Specifies the maximum duration of the tests.

Display Conditions – This option only appears when Test Timeout is set to Enable.

1 – 120 – Sets the Test Timeout period in minutes (inclusive).