beautypg.com

Pvc tests – Paradyne FrameSaver SLV 9664 User Manual

Page 144

background image

Troubleshooting

6-14

9664-A2-GB20-00

March 2000

PVC Tests

PVC tests can be run on a requested DLCI for a selected interface.

H

When PVC tests are on a multiplexed DLCI between FrameSaver devices,
they are nondisruptive to data, so user data can continue to be sent during
a test.

H

If the device at one end of the circuit is not a FrameSaver device, PVC tests
are on a standard DLCI and are disruptive to data. Also, the Connectivity test
would not appear.

Loopback, and send/monitor pattern tests are available for each interface on the
selected DLCI. FrameSaver devices should be at each end of the circuit. If a
PVC Loopback is started at one end of the circuit, the other end can send and
monitor pattern tests.

The example below shows a PVC Test screen for a FrameSaver unit with the
multiplexed DLCI 550 selected. If a standard DLCI was selected, (

Disruptive

),

rather than (

Non-Disruptive

), would be displayed after Test. Also, the

Connectivity test would not appear.

PVC Tests Screen Example

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

ООООООООООООООООООООООООО

main/test/network_pvc

9664

Device Name: Node A

5/26/1999 23:32

NETWORK PVC TESTS

DLCI Number: 550

Test (Non-Disruptive)

Command

Status

Result

PVC Loopback:

Start

Inactive

0:00:00

Send Pattern:

Start

Inactive

0:00:00

Monitor Pattern:

Start

Inactive

0:00:00

Sequence Errors

99999+

Data Errors

99999+

Connectivity:

Start

Inactive

RndTrip Time (ms) 99999

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

Ctrl-a to access these functions, ESC for previous menu

MainMenu

Exit

NOTE:

Errors encountered during these tests may be caused by mismatched CIRs
in the two FrameSaver devices. If errors are detected, verify the CIR
configuration and retest.